ChargeTier LogoChargeTier
Table of Contents

GE Spec Setter Generator Interlock Kit & Inlet Wiring Guide

Connecting a 240V portable generator inlet (NEMA 14-50, L14-30, 14-30, or 6-50) to a GE Spec Setter load center requires a mechanical interlock plate matched to the main breaker layout (THQMV200), a listed THQB 2-pole backfeed breaker, and a mechanical breaker hold-down retainer per NEC 408.36(D).

By , Editor

Fast Answer⚑ Interlock Reference: GE Spec Setter Load Centers
β–Ό
πŸ† Reference Hardware Configuration

Mechanical Interlock Kit (THQMV200) + THQB Backfeed Breaker

⚑ Required Circuit & Conductors

30A or 50A Double-Pole THQB Breaker β€’ 6 AWG THHN Cu (50A Inlet) or 10 AWG Cu (30A Inlet)

βœ“ Code Standard: NEC Article 702.5 & NEC 408.36(D) Backfed Breaker Hold-Down RuleRead Calculation Methodology →

Compatible Generator Inlet Configurations for GE Spec Setter

Comparison of NEMA 14-50, 14-30, 6-50, and L14-30 generator inlets when wired to a GE Spec Setter load center.

Generator InletMax Breaker / AmpsContinuous Load (80%)Max Running WattsCopper Wire GaugePin Configuration
NEMA 14-50 (240V)50A 2-Pole (THQB)40A12,000 W peak6 AWG Cu (THHN)4-wire RV/Generator Inlet
NEMA 14-30 (240V)30A 2-Pole (THQB)24A7,200 W peak10 AWG Cu (THHN)4-wire Dryer/Generator Inlet
NEMA 6-50 (240V)50A 2-Pole (THQB)40A12,000 W peak6 AWG Cu (THHN)3-wire Welder/Generator Inlet
NEMA L14-30 (240V)30A 2-Pole (THQB)24A7,200 W peak10 AWG Cu (THHN)4-wire Twist-Lock Generator Inlet

GE Spec Setter Load Center Configurations & Interlock Reference Matrix

All 10 GE Spec Setter panel variants, main bus ratings, branch breaker types, and interlock kit references.

Panel ConfigurationMain RatingBranch Breaker TypeInterlock Reference Model
General Electric Spec Setter Commercial 200A200AType THQBTHQMV200
General Electric Spec Setter Commercial 100A100AType THQBTHQMV100
General Electric Spec Setter Commercial 125A125AType THQBTHQMV100
General Electric Spec Setter Commercial 150A150AType THQBTHQMV200
General Electric Spec Setter Commercial 200A200AType THQBTHQMV200
General Electric Spec Setter Commercial 225A225AType THQBTHQMV200
General Electric Spec Setter Industrial 100A100AType THQBTHQMV100
General Electric Spec Setter Industrial 200A200AType THQBTHQMV200
General Electric Spec Setter Outdoor 100A100AType THQBTHQMV100
General Electric Spec Setter 42-Space 200A200AType THQBTHQMV200
Technical Wiring Schematic

Generator NEMA 14-50 Inlet β†’ General Electric Spec Setter Commercial 200A Panel Wiring

⚠️ NEC 702.12 Interlock Rule
NEMA 14-50 Inlet240V / 50A Rating Conduit: 6 AWG THHN CopperGeneral Electric Spec Setter Commercial 200ABreaker: Type THQBInterlock MechanicalPrevents Utility FeedbackDouble-Pole 50A
⚑
Mandatory National Electrical Code (NEC) Compliance:Under NEC 702.12, backfeeding a generator into a General Electric panel without a mechanical interlock kit is illegal and extremely dangerous to utility workers. Never connect a suicide cord directly to a live breaker without a verified THQB-compatible interlock mechanism.

Required Hardware Checklist for GE Spec Setter

πŸ”§ Mechanical Interlock Kit (THQMV200)

Matched to GE Spec Setter main-to-branch breaker spacing. Physically prevents turning on the generator backfeed breaker while the main utility breaker is closed.

Check Retailer Availability on Amazon

πŸ”Œ Outdoor Generator Power Inlet Box (30A / 50A)

NEMA 3R weatherproof generator inlet box (NEMA 14-50 / CS6365 for 50A or NEMA L14-30 for 30A) wired to a listed 2-pole THQB backfeed breaker with hold-down kit.

Check Inlet Box Availability on Amazon
Installation Essentials

Required Wiring & Installation Accessories

Verified NEC Compatibility
Required Code$18.99

50A Double-Pole Circuit Breaker

UL-Listed, mandatory for continuous EV charging load under NEC code.

View Deal at Amazon
Top Rated Wire$64.50

6 AWG THHN Copper Wire (50ft Spool)

Heat-resistant 90Β°C copper conductor for conduit installation.

View Deal at Amazon
Fire Safety Must$79.00

Hubbell HBL9450A / Bryant Electric 50A Industrial NEMA 14-50 Outlet

Industrial Grade heavy-duty receptacle (Hubbell HBL9450A / Bryant 50A). Mandatory safety upgrade to prevent melting on high continuous EV loads.

View Deal at Amazon
Protection$12.40

3/4" Schedule 40 PVC Conduit (10ft Lengths)

UV-resistant protection for exposed indoor/outdoor wire runs.

View Deal at Amazon

Interlock Compatibility FAQ: GE Spec Setter

Is a mechanical generator interlock kit compliant with NEC code for GE Spec Setter panels?

Yes. Per NEC Article 702.5, a listed mechanical interlock plate physically prevents both the main utility breaker and the generator backfeed breaker from being turned on simultaneously in a GE Spec Setter load center, and NEC 408.36(D) requires a mechanical hold-down retainer on the backfed plug-on breaker.

What size wire and breaker are required for a 50A or 30A generator inlet on a GE Spec Setter panel?

A 50A generator inlet (NEMA 14-50 or CS6365) requires a 50A double-pole THQB-type breaker with 6 AWG THHN copper wire in conduit (or 6/3 NM-B where permitted). A 30A generator inlet (NEMA L14-30 or 14-30) requires a 30A double-pole THQB-type breaker with 10 AWG copper wire.

Which GE Spec Setter panel ratings are covered on this page?

This guide covers all 10 residential GE Spec Setter configurations, including Spec Setter Commercial 200A, Spec Setter Commercial 100A, Spec Setter Commercial 125A, Spec Setter Commercial 150A, Spec Setter Commercial 200A, Spec Setter Commercial 225A, Spec Setter Industrial 100A, Spec Setter Industrial 200A, Spec Setter Outdoor 100A, Spec Setter 42-Space 200A, using THQB branch breakers and reference interlock kit THQMV200.