1. EV Commute & Panel Parameters
2. Recommended Hardware Package
Order 100% NEC-compliant Level 2 chargers, double-pole breakers, and copper THHN wire directly on Amazon:
Fast Answerβ‘ NEC 625.41 Sizing: Hyundai Ioniq 5 (10.9 kW Onboard AC)βΌ
45A Level 2 EVSE (40 miles replenished in ~1.11 hrs)
60A Double-Pole Breaker β’ 6 AWG THHN Copper Wire in Conduit
Home Level 2 Charging Setup for Hyundai Ioniq 5
Compatible Reference Hardware: Tesla Universal Wall Connector (NEC Article 625 Continuous Load Basis)
Hyundai Ioniq 5 Trims: Battery Capacity & NEC 625 Circuit Sizing
Manufacturer battery capacities, maximum AC onboard charger acceptance rates, and NEC 625.41 (125% continuous load) branch-circuit sizing across all Hyundai Ioniq 5 trim configurations:
| Trim / Variant | Battery (kWh) | Max AC Input | Continuous Load | NEC 125% Breaker | 75Β°C THHN Copper | Efficiency |
|---|---|---|---|---|---|---|
| Hyundai Ioniq 5 β Limited AWD | 77.4 kWh | 10.9 kW | 45A @ 240V | 60A 2-Pole | #6 AWG Cu | 3.3 mi/kWh |
| Hyundai Ioniq 5 β N AWD | 84 kWh | 10.9 kW | 45A @ 240V | 60A 2-Pole | #6 AWG Cu | 2.9 mi/kWh |
| Hyundai Ioniq 5 β Limited AWD | 77.4 kWh | 10.9 kW | 45A @ 240V | 60A 2-Pole | #6 AWG Cu | 3.3 mi/kWh |
| Hyundai Ioniq 5 β SE Standard | 58 kWh | 10.9 kW | 45A @ 240V | 60A 2-Pole | #6 AWG Cu | 3.8 mi/kWh |
| Hyundai Ioniq 5 β SEL AWD | 77.4 kWh | 10.9 kW | 45A @ 240V | 60A 2-Pole | #6 AWG Cu | 3.4 mi/kWh |
Daily Commute Recharge Times for Hyundai Ioniq 5 (10.9 kW Level 2)
Estimated daily energy consumption and Level 2 recharge durations across 10 to 100 daily commute miles (at 3.3 mi/kWh and $0.16/kWh reference electricity rate):
| Daily Round-Trip Commute | Energy Used (kWh) | Level 2 Recharge Time (10.9 kW) | Est. Daily Cost ($0.16/kWh) |
|---|---|---|---|
| 10 Miles / Day | 3 kWh | 17 min | $0.48 |
| 25 Miles / Day | 7.6 kWh | 42 min | $1.22 |
| 40 Miles / Day | 12.1 kWh | 1.11 hrs (67 min) | $1.94 |
| 60 Miles / Day | 18.2 kWh | 1.67 hrs (100 min) | $2.91 |
| 80 Miles / Day | 24.2 kWh | 2.22 hrs (133 min) | $3.87 |
| 100 Miles / Day | 30.3 kWh | 2.78 hrs (167 min) | $4.85 |
Compatible EV Chargers for 45A Continuous Load
Tesla Universal Wall Connector
48A Max Output β’ Hardwired Capable
Emporia EV Charger
48A Max Output β’ Hardwired Capable
ChargePoint Home Flex
50A Max Output β’ Hardwired Capable
NEMA Outlet & Wire Gauge Compatibility Matrix for Hyundai Ioniq 5
Hyundai Ioniq 5 Charge & Infrastructure Sizer
Battery: 77.4 kWh | Max AC Input: 10.9 kW | Efficiency: 3.3 mi/kWh
Energy & Economic Impact
12.12 kWh
4424 kWh/yr
$708
Time to Replenish 40 Miles
NEC Code Specs (125% Rule)
Electrical SafetyNEC Code Electrical Sizing & Voltage Drop Engine
5-Year Total Cost of Ownership & Fuel Savings for Hyundai Ioniq 5
Total Cost of Ownership (TCO) Breakdown
Hyundai Ioniq 5 (40 Mi/Day)
Required Wiring & Installation Accessories
60A Double-Pole Circuit Breaker
UL-Listed, mandatory for continuous EV charging load under NEC code.
4/6 AWG THHN Copper Wire (50ft Spool)
Heat-resistant 90Β°C copper conductor for conduit installation.
Hubbell HBL9450A / Bryant Electric 50A Industrial NEMA 14-50 Outlet
Industrial Grade heavy-duty receptacle (Hubbell HBL9450A / Bryant 50A). Mandatory safety upgrade to prevent melting on high continuous EV loads.
3/4" Schedule 40 PVC Conduit (10ft Lengths)
UV-resistant protection for exposed indoor/outdoor wire runs.
Related Charger Comparisons & Panel Interlock Guides for Hyundai Owners
Top Charger Comparison Guides:
Panel Interlock Compatibility Guides:
EV Sizing FAQ for Hyundai Ioniq 5
What breaker size and wire gauge do I need for a Hyundai Ioniq 5 Level 2 charger?
With a 10.9 kW onboard AC charger (45A continuous load at 240V), NEC Section 625.41 requires sizing the branch circuit at 125% of continuous load: a 60A double-pole breaker with #6 AWG THHN copper wire in conduit (or #4 AWG NM-B Romex where permitted by code).
How long does it take to recharge a Hyundai Ioniq 5 for a 40-mile daily commute?
At 3.3 miles per kWh, a 40-mile daily commute uses approximately 12.1 kWh. At 10.9 kW Level 2 AC output, replenishing 40 miles takes roughly 1.11 hours.
Can I use a NEMA 14-50 plug-in outlet for my Hyundai Ioniq 5 instead of hardwiring?
While an EV-rated NEMA 14-50 receptacle supports up to 40A continuous charging (9.6 kW) on a 50A breaker, hardwiring on a 60A circuit is required under NEC 625.41 to deliver full 45A (10.9 kW) charging.