DEWALT Level 2 Portable NACS 32A vs. Enel X JuiceBox 40: Level 2 EV Charger Spec Comparison
Side-by-side specification comparison of DEWALT Level 2 Portable NACS 32A (32A max) and Enel X JuiceBox 40 (40A max) across 32A, 40A, and 48A residential Level 2 branch circuits.
By Gil Sapir, Editor
Fast Answerβ‘ Spec Summary: DEWALT Level 2 Portable NACS 32A vs Enel X JuiceBox 40βΌ
DEWALT Level 2 Portable NACS 32A (Approx. $349 Reference Price)
50A Double-Pole Breaker (for 40A Max Output) β’ 8 AWG THHN Copper
Compatible EV Chargers for 40A Continuous Load
Tesla Universal Wall Connector
48A Max Output β’ Hardwired Capable
Emporia EV Charger
48A Max Output β’ Hardwired Capable
ChargePoint Home Flex
50A Max Output β’ Hardwired Capable
Comparing DEWALT vs Enel X on a 40A Load
Comparing published manufacturer specifications, DEWALT Level 2 Portable NACS 32A has the lower approximate reference price by ~$170. Compare maximum continuous amperage (32A vs 40A) and connector compatibility below.
DEWALT Level 2 Portable NACS 32A
Lower Ref. PriceConsider this if: You need up to 32A continuous output and matching connector support.
- β Approx. Ref. Price: $349 (Check Retailer)
- β Max Output: 32 Amps
Enel X JuiceBox 40
Consider this if: You want up to 40A continuous output and its specific enclosure/cord configuration.
- β Approx. Ref. Price: $519 (Check Retailer)
- β Max Output: 40 Amps
DEWALT Level 2 Portable NACS 32A vs. Enel X JuiceBox 40
| Feature / Spec | DEWALT Level 2 Portable NACS 32A | Enel X JuiceBox 40 |
|---|---|---|
| Approx. Reference Price (Check Retailer) | ~$349π° Lower Reference Price | ~$519 |
| Max Amperage Rating | 32 Amps (7.7 kW) | 40 Amps (9.6 kW) |
| Hardwire Support | β οΈ Plug-in Only | β Yes (Hardwire Capable) |
| Supported Plug Standard | NACS | J1772 |
| Enclosure & Outdoor Rating | NEMA 4 / 3R (Indoor / Outdoor Weatherproof) | NEMA 4 / 3R (Indoor / Outdoor Weatherproof) |
32A, 40A & 48A Branch-Circuit Configuration Matrix (NEC 625.41)
Comparison of breaker ratings, 75Β°C copper wire gauges, and charger output across standard residential Level 2 circuit tiers.
| Continuous Load | NEC 125% Breaker | Power @ 240V | Copper Wire Gauge | Installation Method | DEWALT Level 2 Portable NACS 32A | Enel X JuiceBox 40 |
|---|---|---|---|---|---|---|
| 32A Continuous | 40A 2-Pole | 7.7 kW | 8 AWG Cu (75Β°C THHN) | Hardwired or NEMA 14-50 | Operates at 32A (7.7 kW) | Operates at 32A (7.7 kW) |
| 40A Continuous | 50A 2-Pole | 9.6 kW | 8 AWG THHN / 6 AWG NM-B | Hardwired or EV-Rated NEMA 14-50 | Capped at 32A | Operates at 40A (9.6 kW) |
| 48A Continuous | 60A 2-Pole | 11.5 kW | 6 AWG Cu (75Β°C THHN in Conduit) | Hardwired Only (NEC 625) | Capped at 32A (9.6 kW) | Capped at 40A (9.6 kW) |
Tesla Model Y Charge & Infrastructure Sizer
Battery: 81 kWh | Max AC Input: 9.6 kW | Efficiency: 3.6 mi/kWh
Energy & Economic Impact
11.11 kWh
4056 kWh/yr
$649
Time to Replenish 40 Miles
NEC Code Specs (125% Rule)
Electrical SafetyHardware Specification Summaries

DEWALT Level 2 Portable NACS 32A
Based on manufacturer specifications, the DEWALT Level 2 Portable NACS 32A is rated for up to 32A continuous duty (7.7 kW at 240V) with NACS connector support. Below is a summary of published specifications and installation considerations.
Key Capabilities
- β’Supports up to 32A continuous output
- β’Indoor/outdoor rated weatherproof enclosure
- β’UL 2594 safety standard compliant
Installation Notes
- β’Requires 50A branch circuit for maximum output
- β’Verify local permit and GFCI breaker requirements with a licensed electrician
Manufacturer Specifications

Enel X JuiceBox 40
Based on manufacturer specifications, the Enel X JuiceBox 40 is rated for up to 40A continuous duty (9.6 kW at 240V) with J1772 connector support. Below is a summary of published specifications and installation considerations.
Key Capabilities
- β’Supports up to 40A continuous output
- β’Indoor/outdoor rated weatherproof enclosure
- β’UL 2594 safety standard compliant
Installation Notes
- β’Requires 50A branch circuit for maximum output
- β’Verify local permit and GFCI breaker requirements with a licensed electrician
Manufacturer Specifications
Required Wiring & Installation Accessories
50A Double-Pole Circuit Breaker
UL-Listed, mandatory for continuous EV charging load under NEC code.
6 AWG THHN Copper Wire (50ft Spool)
Heat-resistant 90Β°C copper conductor for conduit installation.
Hubbell HBL9450A / Bryant Electric 50A Industrial NEMA 14-50 Outlet
Industrial Grade heavy-duty receptacle (Hubbell HBL9450A / Bryant 50A). Mandatory safety upgrade to prevent melting on high continuous EV loads.
3/4" Schedule 40 PVC Conduit (10ft Lengths)
UV-resistant protection for exposed indoor/outdoor wire runs.
Frequently Asked Questions: DEWALT Level 2 Portable NACS 32A vs Enel X JuiceBox 40
What is the main specification difference between DEWALT Level 2 Portable NACS 32A and Enel X JuiceBox 40?
DEWALT Level 2 Portable NACS 32A is rated for up to 32A continuous output (7.7 kW at 240V) with NACS support (approx. $349), while Enel X JuiceBox 40 is rated for up to 40A continuous output (9.6 kW at 240V) with J1772 support (approx. $519).
What breaker and wire size do DEWALT Level 2 Portable NACS 32A and Enel X JuiceBox 40 require under NEC 625.41?
Under NEC Article 625.41, EV chargers are continuous loads sized at 125%: a 32A setting requires a 40A breaker (#8 AWG THHN), a 40A setting requires a 50A breaker (#8 AWG THHN or #6 AWG NM-B), and a 48A setting requires a 60A hardwired circuit (#6 AWG THHN copper in conduit).
Can both DEWALT Level 2 Portable NACS 32A and Enel X JuiceBox 40 be installed on a 40A or 50A circuit?
Most adjustable Level 2 EVSE units can be derated via internal rotary switches or installer software during commissioning to match 40A (32A continuous) or 50A (40A continuous) branch circuits per NEC 625.42. Verify exact dip-switch or app configuration steps in the manufacturer installation manual.